{"id":21888,"date":"2025-12-02T08:33:45","date_gmt":"2025-12-02T08:33:45","guid":{"rendered":"https:\/\/burmeier-ingenieure.de\/?p=21888"},"modified":"2025-12-02T08:38:46","modified_gmt":"2025-12-02T08:38:46","slug":"luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen","status":"publish","type":"post","link":"https:\/\/burmeier-ingenieure.de\/en\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/","title":{"rendered":"Air monitoring in contaminated areas: safety with PID measurements"},"content":{"rendered":"<p>Remediation and exploration work in contaminated areas places high demands on occupational safety. Gases and vapours that remain invisible to humans can have dangerous effects even in small quantities. This is why continuous monitoring of breathing air is of central importance. Modern measuring devices make it possible to recognise acute risks such as fire and explosion hazards as well as oxygen deficiency, but also to reliably assess long-term exposure.<\/p>\n\n\n\n<p>At the heart of these protective measures are powerful photoionisation detectors (PID), which have established themselves as a reliable solution for monitoring organic pollutants. With well-founded expertise, the <strong>Prof. Burmeier Ingenieurgesellschaft mbH - Member of the SIERA Alliance<\/strong> - projects in the field of contaminated site management and ensures that remediation work can be carried out safely, efficiently and in accordance with regulations. This is another example of the SIERA Alliance's commitment: <em>Engineering for a Better Tomorrow.<\/em><\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Importance of reliable air monitoring<\/strong><\/h3>\n\n\n\n<p>Air monitoring is an integral part of occupational health and safety when working in polluted soils, contaminated sites or chemically contaminated buildings. It serves two main purposes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Recognition of acute dangers:<\/strong><br>These include explosive atmospheres, oxygen deficiency or toxic gas emissions.<\/li>\n\n\n\n<li><strong>Assessment of chronic hazards:<\/strong><br>Many pollutants develop their effects over longer periods of time. Continuous measurement is therefore necessary in order to recognise limit value violations in good time and initiate appropriate measures.<\/li>\n<\/ul>\n\n\n\n<p>While multi-gas measuring devices traditionally detect acute hazards, PIDs enable the specific monitoring of organic vapours - a decisive factor in the remediation of contaminated sites, paint shops, chemical plants or former tank farms.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>How a photoionisation detector works<\/strong><\/h3>\n\n\n\n<p>A PID is a highly sensitive measuring device based on the ionisation of organic molecules. Its functional structure consists of three central components:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Internal pump:<\/strong> Draws in the ambient air.<\/li>\n\n\n\n<li><strong>UV light source:<\/strong> High-energy rays detach electrons from organic molecules.<\/li>\n\n\n\n<li><strong>Ionisation chamber:<\/strong> Ionisation generates an electric current whose strength is proportional to the concentration of the pollutants.<\/li>\n<\/ul>\n\n\n\n<p>Electronic amplification and calibration are used to generate a measurable value on the display. Standard calibration is usually carried out with isobutylene - a non-hazardous substance that is ideal for adjusting measuring devices.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Why UV energy is crucial<\/strong><\/h3>\n\n\n\n<p>Not all substances can be ionised. The required ionisation energy of a substance is a physical constant. The higher the energy of the UV lamp, the more substances can be ionised.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Typical UV lamp options:<\/strong><\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>UV lamp<\/strong><\/td><td><strong>Energy (eV)<\/strong><\/td><td><strong>Recordable substance groups<\/strong><\/td><\/tr><tr><td><strong>9.8 eV<\/strong><\/td><td>low<\/td><td>Selected solvents<\/td><\/tr><tr><td><strong>10.6 eV<\/strong><\/td><td>Standard<\/td><td>Alcohols, aromatics, amines, ethers, esters and much more.<\/td><\/tr><tr><td><strong>11.7 eV<\/strong><\/td><td>high<\/td><td>Broad spectrum of organic compounds<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>The standard for refurbishment work is the <strong>10.6 eV lamp<\/strong>, which already makes a wide range of organic chemicals detectable - including hydrocarbons, aldehydes, acrylates and mercaptans.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post1-1-scaled.jpg\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"492\" src=\"https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post1-1-1024x492.jpg\" alt=\"\" class=\"wp-image-21890\" srcset=\"https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post1-1-1024x492.jpg 1024w, https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post1-1-300x144.jpg 300w, https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post1-1-768x369.jpg 768w, https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post1-1-1536x737.jpg 1536w, https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post1-1-2048x983.jpg 2048w, https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post1-1-18x9.jpg 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Limits and possibilities of a PID<\/strong><\/h4>\n\n\n\n<p>A PID provides <strong>Sum signals<\/strong>, no individual substance identification. This means:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Individual substances cannot be determined in isolation.<\/li>\n\n\n\n<li>If individual substances are known to be present, additional tests must be carried out in the laboratory.<\/li>\n\n\n\n<li>To correctly assess hazards, the percentage composition of the air components is crucial.<\/li>\n<\/ul>\n\n\n\n<p>Exact threshold values can only be derived through laboratory analyses, above which protective measures such as ventilation fans, extraction systems or personal protective equipment become necessary.<\/p>\n\n\n\n<p>These correlations illustrate why the use of trained specialists is essential. Measurement results must be interpreted expertly in order to organise work areas safely. This is precisely where the <strong>Prof. Burmeier Ingenieurgesellschaft mbH - Member of the SIERA Alliance<\/strong> - with expertise, experience and modern measurement technology.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Typical areas of application in the environmental and contaminated sites sector<\/strong><\/h4>\n\n\n\n<p>The possible applications of a PID are diverse and closely linked to working practice in environmental and contaminated site management. These include<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Continuous monitoring during renovation work<\/strong><br>z. e.g. in the case of soil air pollution caused by BTEX, LHKW or other volatile organic compounds.<\/li>\n\n\n\n<li><strong>Inspection of drill cores<\/strong><br>to quickly assess whether solvents or other pollutants are present in the substrate.<\/li>\n\n\n\n<li><strong>Leak detection in industrial plants<\/strong><br>Early detection of substance leaks in technical installations.<\/li>\n\n\n\n<li><strong>Containment of damage areas in the event of chemical accidents<\/strong><br>Quick orientation for emergency services to secure danger zones.<\/li>\n<\/ul>\n\n\n\n<p>In all these cases, PGD serves as a reliable screening tool that enables quick decisions to be made.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Professional implementation by trained personnel<\/strong><\/h3>\n\n\n\n<p>The results of PID measurements require expertise and experience. Only trained specialists can:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Classify measured values correctly,<\/li>\n\n\n\n<li>Correctly assess limit value violations,<\/li>\n\n\n\n<li>derive the necessary protective measures,<\/li>\n\n\n\n<li>Create documentation in accordance with technical regulations.<\/li>\n<\/ul>\n\n\n\n<p>Prof. Burmeier Ingenieurgesellschaft mbH - a member of the SIERA Alliance - provides qualified personnel and state-of-the-art measuring equipment for this purpose. In contaminated site remediation projects, the company supports clients in creating safe working conditions - from preparation and measurement monitoring to final assessment. In this way, the company contributes to the safe execution of work in contaminated areas and thus follows the guiding principle of the SIERA Alliance: <em>Engineering for a Better Tomorrow.<\/em><\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>FAQ<\/strong><\/h4>\n\n\n\n<p>1. <strong>Why is a PID important for refurbishment work?<\/strong><br>Because it detects organic pollutants in the air very sensitively and thus makes health and explosion hazards visible at an early stage.<\/p>\n\n\n\n<p>2. <strong>Can a PID differentiate between individual substances?<\/strong><br>No, it measures total concentrations. Laboratory tests are required for individual substance analyses.<\/p>\n\n\n\n<p>3. <strong>How often does a PID need to be calibrated?<\/strong><br>Regularly, often before each use. The standard calibration is carried out with isobutylene.<\/p>\n\n\n\n<p>4. <strong>Are UV lamps replaceable?<\/strong><br>Yes, the number of detectable substances varies depending on the lamp.<\/p>\n\n\n\n<p>5. <strong>Who is authorised to carry out PID measurements?<\/strong><br>Only trained specialists, as the evaluation of the measurement results requires specialised knowledge.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Conclusion<\/strong><\/h4>\n\n\n\n<p>Sound air monitoring is the key to safe remediation work in contaminated areas. Photoionisation detectors offer an efficient and fast way of detecting organic pollutants in the air - provided they are used correctly.<\/p>\n\n\n\n<p>Thanks to the combination of qualified personnel and state-of-the-art measurement technology, the <strong><a href=\"https:\/\/burmeier-ingenieure.de\/en\/\" target=\"_blank\" rel=\"noreferrer noopener\">Prof. Burmeier Ingenieurgesellschaft mbH<\/a> - Member of the SIERA Alliance<\/strong> - reliable metrological support for contaminated sites and remediation projects. In this way, the company creates safety, transparency and trust - today and in the spirit of the common claim of the SIERA Alliance: <em>Engineering for a Better Tomorrow.<\/em><\/p>\n\n\n\n<p>\u27a1\ufe0f <strong>Get in touch now:<\/strong><br>Find out how Prof. Burmeier Ingenieurgesellschaft mbH - a member of the SIERA Alliance - can provide professional support for your refurbishment project.<\/p>","protected":false},"excerpt":{"rendered":"<p>Remediation and exploration work in contaminated areas places high demands on occupational safety. Gases and vapours that remain invisible to humans,<\/p>","protected":false},"author":124,"featured_media":21891,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[74],"tags":[],"class_list":["post-21888","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-luftueberwachung"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Luft\u00fcberwachung in kontaminierten Bereichen: Sicherheit mit PID-Messungen<\/title>\n<meta name=\"description\" content=\"Wie moderne Luft\u00fcberwachung mit PID-Messger\u00e4ten Sanierungsarbeiten absichert \u2013 Expertise von Prof. Burmeier Ingenieurgesellschaft mbH \u2013 Mitglied der SIERA Allianz.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/burmeier-ingenieure.de\/en\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Luft\u00fcberwachung in kontaminierten Bereichen: Sicherheit mit PID-Messungen\" \/>\n<meta property=\"og:description\" content=\"Wie moderne Luft\u00fcberwachung mit PID-Messger\u00e4ten Sanierungsarbeiten absichert \u2013 Expertise von Prof. Burmeier Ingenieurgesellschaft mbH \u2013 Mitglied der SIERA Allianz.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/burmeier-ingenieure.de\/en\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/\" \/>\n<meta property=\"og:site_name\" content=\"Prof. Burmeier Ingenieurgesellschaft mbH\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-02T08:33:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-02T08:38:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post-5-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1229\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Sayyid Atak Ahmed\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sayyid Atak Ahmed\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/\"},\"author\":{\"name\":\"Sayyid Atak Ahmed\",\"@id\":\"https:\/\/burmeier-ingenieure.de\/en\/#\/schema\/person\/136d343abb3739a3e7bb761216dc016e\"},\"headline\":\"Luft\u00fcberwachung in kontaminierten Bereichen: Sicherheit mit PID-Messungen\",\"datePublished\":\"2025-12-02T08:33:45+00:00\",\"dateModified\":\"2025-12-02T08:38:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/\"},\"wordCount\":957,\"image\":{\"@id\":\"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post-5-scaled.jpg\",\"articleSection\":[\"Luft\u00fcberwachung\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/\",\"url\":\"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/\",\"name\":\"Luft\u00fcberwachung in kontaminierten Bereichen: Sicherheit mit PID-Messungen\",\"isPartOf\":{\"@id\":\"https:\/\/burmeier-ingenieure.de\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post-5-scaled.jpg\",\"datePublished\":\"2025-12-02T08:33:45+00:00\",\"dateModified\":\"2025-12-02T08:38:46+00:00\",\"author\":{\"@id\":\"https:\/\/burmeier-ingenieure.de\/en\/#\/schema\/person\/136d343abb3739a3e7bb761216dc016e\"},\"description\":\"Wie moderne Luft\u00fcberwachung mit PID-Messger\u00e4ten Sanierungsarbeiten absichert \u2013 Expertise von Prof. Burmeier Ingenieurgesellschaft mbH \u2013 Mitglied der SIERA Allianz.\",\"breadcrumb\":{\"@id\":\"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#primaryimage\",\"url\":\"https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post-5-scaled.jpg\",\"contentUrl\":\"https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post-5-scaled.jpg\",\"width\":2560,\"height\":1229},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/burmeier-ingenieure.de\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Luft\u00fcberwachung in kontaminierten Bereichen: Sicherheit mit PID-Messungen\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/burmeier-ingenieure.de\/en\/#website\",\"url\":\"https:\/\/burmeier-ingenieure.de\/en\/\",\"name\":\"Prof. Burmeier Ingenieurgesellschaft mbH\",\"description\":\"Partner for public clients and commercial enterprises\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/burmeier-ingenieure.de\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/burmeier-ingenieure.de\/en\/#\/schema\/person\/136d343abb3739a3e7bb761216dc016e\",\"name\":\"Sayyid Atak Ahmed\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/secure.gravatar.com\/avatar\/908f434da7b4f603e58e5800090dd96342edeb7b99e63ebe51a8bebcd4278b64?s=96&d=mm&r=g\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/908f434da7b4f603e58e5800090dd96342edeb7b99e63ebe51a8bebcd4278b64?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/908f434da7b4f603e58e5800090dd96342edeb7b99e63ebe51a8bebcd4278b64?s=96&d=mm&r=g\",\"caption\":\"Sayyid Atak Ahmed\"},\"url\":\"https:\/\/burmeier-ingenieure.de\/en\/author\/syed-aatik-ahmedeutech-org\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Air monitoring in contaminated areas: safety with PID measurements","description":"Wie moderne Luft\u00fcberwachung mit PID-Messger\u00e4ten Sanierungsarbeiten absichert \u2013 Expertise von Prof. Burmeier Ingenieurgesellschaft mbH \u2013 Mitglied der SIERA Allianz.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/burmeier-ingenieure.de\/en\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/","og_locale":"en_GB","og_type":"article","og_title":"Luft\u00fcberwachung in kontaminierten Bereichen: Sicherheit mit PID-Messungen","og_description":"Wie moderne Luft\u00fcberwachung mit PID-Messger\u00e4ten Sanierungsarbeiten absichert \u2013 Expertise von Prof. Burmeier Ingenieurgesellschaft mbH \u2013 Mitglied der SIERA Allianz.","og_url":"https:\/\/burmeier-ingenieure.de\/en\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/","og_site_name":"Prof. Burmeier Ingenieurgesellschaft mbH","article_published_time":"2025-12-02T08:33:45+00:00","article_modified_time":"2025-12-02T08:38:46+00:00","og_image":[{"width":2560,"height":1229,"url":"https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post-5-scaled.jpg","type":"image\/jpeg"}],"author":"Sayyid Atak Ahmed","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Sayyid Atak Ahmed","Estimated reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#article","isPartOf":{"@id":"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/"},"author":{"name":"Sayyid Atak Ahmed","@id":"https:\/\/burmeier-ingenieure.de\/en\/#\/schema\/person\/136d343abb3739a3e7bb761216dc016e"},"headline":"Luft\u00fcberwachung in kontaminierten Bereichen: Sicherheit mit PID-Messungen","datePublished":"2025-12-02T08:33:45+00:00","dateModified":"2025-12-02T08:38:46+00:00","mainEntityOfPage":{"@id":"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/"},"wordCount":957,"image":{"@id":"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#primaryimage"},"thumbnailUrl":"https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post-5-scaled.jpg","articleSection":["Luft\u00fcberwachung"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/","url":"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/","name":"Air monitoring in contaminated areas: safety with PID measurements","isPartOf":{"@id":"https:\/\/burmeier-ingenieure.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#primaryimage"},"image":{"@id":"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#primaryimage"},"thumbnailUrl":"https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post-5-scaled.jpg","datePublished":"2025-12-02T08:33:45+00:00","dateModified":"2025-12-02T08:38:46+00:00","author":{"@id":"https:\/\/burmeier-ingenieure.de\/en\/#\/schema\/person\/136d343abb3739a3e7bb761216dc016e"},"description":"Wie moderne Luft\u00fcberwachung mit PID-Messger\u00e4ten Sanierungsarbeiten absichert \u2013 Expertise von Prof. Burmeier Ingenieurgesellschaft mbH \u2013 Mitglied der SIERA Allianz.","breadcrumb":{"@id":"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#primaryimage","url":"https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post-5-scaled.jpg","contentUrl":"https:\/\/burmeier-ingenieure.de\/wp-content\/uploads\/2025\/12\/Blog-post-5-scaled.jpg","width":2560,"height":1229},{"@type":"BreadcrumbList","@id":"https:\/\/burmeier-ingenieure.de\/luftueberwachung-in-kontaminierten-bereichen-sicherheit-mit-pid-messungen\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/burmeier-ingenieure.de\/"},{"@type":"ListItem","position":2,"name":"Luft\u00fcberwachung in kontaminierten Bereichen: Sicherheit mit PID-Messungen"}]},{"@type":"WebSite","@id":"https:\/\/burmeier-ingenieure.de\/en\/#website","url":"https:\/\/burmeier-ingenieure.de\/en\/","name":"Prof. Burmeier Ingenieurgesellschaft mbH","description":"Partner for public clients and commercial enterprises","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/burmeier-ingenieure.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/burmeier-ingenieure.de\/en\/#\/schema\/person\/136d343abb3739a3e7bb761216dc016e","name":"Sayyid Atak Ahmed","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/908f434da7b4f603e58e5800090dd96342edeb7b99e63ebe51a8bebcd4278b64?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/908f434da7b4f603e58e5800090dd96342edeb7b99e63ebe51a8bebcd4278b64?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/908f434da7b4f603e58e5800090dd96342edeb7b99e63ebe51a8bebcd4278b64?s=96&d=mm&r=g","caption":"Sayyid Atak Ahmed"},"url":"https:\/\/burmeier-ingenieure.de\/en\/author\/syed-aatik-ahmedeutech-org\/"}]}},"_links":{"self":[{"href":"https:\/\/burmeier-ingenieure.de\/en\/wp-json\/wp\/v2\/posts\/21888","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/burmeier-ingenieure.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/burmeier-ingenieure.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/burmeier-ingenieure.de\/en\/wp-json\/wp\/v2\/users\/124"}],"replies":[{"embeddable":true,"href":"https:\/\/burmeier-ingenieure.de\/en\/wp-json\/wp\/v2\/comments?post=21888"}],"version-history":[{"count":2,"href":"https:\/\/burmeier-ingenieure.de\/en\/wp-json\/wp\/v2\/posts\/21888\/revisions"}],"predecessor-version":[{"id":21893,"href":"https:\/\/burmeier-ingenieure.de\/en\/wp-json\/wp\/v2\/posts\/21888\/revisions\/21893"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/burmeier-ingenieure.de\/en\/wp-json\/wp\/v2\/media\/21891"}],"wp:attachment":[{"href":"https:\/\/burmeier-ingenieure.de\/en\/wp-json\/wp\/v2\/media?parent=21888"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/burmeier-ingenieure.de\/en\/wp-json\/wp\/v2\/categories?post=21888"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/burmeier-ingenieure.de\/en\/wp-json\/wp\/v2\/tags?post=21888"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}